Define
Isolated bus ducts represent a special type of conductor capable of transmitting
currents of high ratings between Main Generator and Step-up Transformer in Nuclear/
Hydroelectric/ thermal/combined power plant.

Production Range
Production Range
•

Voltage: Up to 36kV, 25kA, 170kV BIL

•

Connection: Fixed point, Move point, Flexible part, Expansion joint

Other Equipment
•

Pressurization System, Breather System, Heater System

Application
•

Power Plant Step-UP Transformer

•

High Current Generator

Technical Advantage
•

Perfectly ability to withstand short-circuit

•

High strength of withstand current

•

No electric magnetic induction overheat and inductive disturbance

•

High efficiency of applying current

•

High air-tighten and maintenance free

•

High insulation strength

•

Easy handling

Specification
Insulation Level

Rated Current(kA)

Withstand Voltage(kV)

BIL(kV)

12kV

2.5, 4, 6.3, 8
10, 12.5, 14

28

75

17.5kV

2.5, 4, 6.3, 8
10, 12.5, 14

50

110

24kV

2.5, 4, 6.3, 8
10, 12.5, 14, 16
18, 20, 22, 25

50

125

36kV

2.5, 4, 6.3, 8
10, 12.5, 14, 16
18, 20, 22, 25

70

170

IPB(Isolated Phase Busduct)

ILJIN ELECTRIC IPB Report

Reference
1995	

Tae-an Thermal Power Plant #3, #4

1997	

Bo-ryung Thermal Power Plant

1998	

Dong-hae Thermal Power Plant

2002	

Bu-san Combined Cycle Power Plant

2004	

Young-hung Thermal Power Plant

2006	

Tae-an Thermal Power Plant #7, #8

2009	

Young-wol Combined Cycle Power Plant

[Young-hung Power Plant:2003]

[Bu-san Power Plant:2002]

[Tae-an Power Plant:2006]

[Young-wol Power Plant:2009]

ILJIN ELECTRIC CO., LTD. T&D DIVISION
SUWON PLANT
112-83, Annyung-dong, Hwasung-si, Kyunggi-do, Korea Tel.+82-31-220-0523 Fax .+82-31-220-0519
SEOUL OFFICE
11F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Tel.+82-2-707-9734 Fax.+82-2-707-9655



...
ILJIN ELECTRIC IPB Report
IPB(Isolated Phase Busduct)
WWW.ILJINELECTRIC.CO.KR
Isolated bus ducts represent a special type of conductor capable of transmitting
currents of high ratings between Main Generator and Step-up Transformer in Nuclear/
Hydroelectric/ thermal/combined power plant.
Perfectly ability to withstand short-circuit
High strength of withstand current
No electric magnetic induction overheat and inductive disturbance
High efficiency of applying current
High air-tighten and maintenance free
High insulation strength
Easy handling
Production Range
Voltage: Up to 36kV, 25kA, 170kV BIL
Connection: Fixed point, Move point, Flexible part, Expansion joint
Other Equipment
Pressurization System, Breather System, Heater System
Application
Power Plant Step-UP Transformer
High Current Generator
Insulation Level Rated Current(kA) Withstand Voltage(kV) BIL(kV)
12kV
2.5, 4, 6.3, 8
10, 12.5, 14
28 75
17.5kV
2.5, 4, 6.3, 8
10, 12.5, 14
50 110
24kV
2.5, 4, 6.3, 8
10, 12.5, 14, 16
18, 20, 22, 25
50 125
36kV
2.5, 4, 6.3, 8
10, 12.5, 14, 16
18, 20, 22, 25
70 170
Define
Technical Advantage
Production Range
Specification
IPB(Isolated Phase Busduct) - Trang 2
IPB(Isolated Phase Busduct) - Người đăng: tdcntta
5 Tài liệu rất hay! Được đăng lên bởi - 1 giờ trước Đúng là cái mình đang tìm. Rất hay và bổ ích. Cảm ơn bạn!
2 Vietnamese
IPB(Isolated Phase Busduct) 9 10 516